最具影响力的数字化技术在线社区

dbadoudou 发表于 2014-8-21 08:31:42

EMC LUN ON HP UNIX盘符不一致的解决方法

EMC LUN ON HP UNIX盘符不一致的解决方法1.同一块LUN;找出对应盘符的唯一ID,并找出其WWN
cd /dev/rdisk
节点1
# ls -l /dev/rdisk/disk161
crw-r--r--   1 root       sys         13 0x000030 Aug 20 13:53 /dev/rdisk/disk161
节点2
# ls -l /dev/rdisk/disk162
crw-r--r--   1 root       sys         13 0x000034 Aug 20 13:53 /dev/rdisk/disk162

2.创建新的盘符,并设置成双节点一致
cd /dev/rdisk
节点1
mknod /dev/rdisk/disk163 c 13 0x000030 <=唯一的
节点2
mknod /dev/rdisk/disk163 c 13 0x000034 <=唯一的

3.验证盘符是否一致
节点1
# ioscan -funN -C disk
Class   IH/W PathDriver S/W State   H/W Type   Description
===================================================================
disk    16164000/0xfa00/0x30esdisk   CLAIMED   DEVICE       DGC   RAID 5
                      /dev/disk/disk161    /dev/rdisk/disk163

节点2
# ioscan -funN -C disk
Class   IH/W PathDriver S/W State   H/W Type   Description
===================================================================
disk    16264000/0xfa00/0x34esdisk   CLAIMED   DEVICE       DGC   RAID 5
                      /dev/disk/disk162   /dev/rdisk/disk163
##注意:2个节点的/dev/disk是有所有不同的,一个是disk161,一个是disk162,所以如果需要使用/dev/disk一定要注意哦。##

3-1.使用powermt验证
命令: powermt display dev=all
节点1
# powermt display dev=all
Pseudo name=disk163
VNX ID=FCN00114900102
Logical device ID=6006016045D02E00FA8E1E687A26E411
state=alive; policy=CLAROpt; queued-IOs=0
Owner: default=SP A, current=SP A       Array failover mode: 4
==============================================================================
--------------- Host ---------------   - Stor --- I/O Path --   -- Stats ---
###HW Path               I/O Paths    Interf.Mode   State   Q-IOs Errors
==============================================================================
   1 0/6/0/0/0/0/2/0/0/1.0x5006016c47200986.0x7000000000000 c9t0d7      SP B4    active   alive      0      0
   1 0/6/0/0/0/0/2/0/0/1.0x5006016447200986.0x7000000000000 c7t0d7      SP A4    active   alive      0      0
   0 0/6/0/0/0/0/2/0/0/0.0x5006016847200986.0x7000000000000 c5t0d7      SP B0    active   alive      0      0
   0 0/6/0/0/0/0/2/0/0/0.0x5006016047200986.0x7000000000000 c3t0d7      SP A0    active   alive      0      0
节点2
# powermt display dev=all
Pseudo name=disk163
VNX ID=FCN00114900102
Logical device ID=6006016045D02E00FA8E1E687A26E411
state=alive; policy=CLAROpt; queued-IOs=0
Owner: default=SP A, current=SP A       Array failover mode: 4
==============================================================================
--------------- Host ---------------   - Stor --- I/O Path --   -- Stats ---
###HW Path               I/O Paths    Interf.Mode   State   Q-IOs Errors
==============================================================================
   1 0/6/0/0/0/0/2/0/0/1.0x5006016c47200986.0x7000000000000 c9t0d7      SP B4    active   alive      0      0
   1 0/6/0/0/0/0/2/0/0/1.0x5006016447200986.0x7000000000000 c7t0d7      SP A4    active   alive      0      0
   0 0/6/0/0/0/0/2/0/0/0.0x5006016847200986.0x7000000000000 c5t0d7      SP B0    active   alive      0      0
   0 0/6/0/0/0/0/2/0/0/0.0x5006016047200986.0x7000000000000 c3t0d7      SP A0    active   alive      0      0

##注意:千万不要使用这个命令insf -e,此命令会继续使用系统默认的重命名,如果重命名后盘符就又不一致了。##


页: [1]
查看完整版本: EMC LUN ON HP UNIX盘符不一致的解决方法